Septic Contractors
California’s Authorized Hoot Manufacturer & Distributor
We supply Hoot systems, components, and installation support to licensed septic contractors throughout California. Clean documentation, reliable delivery, and contractor-first service — every time.
Built Around the Way Contractors Work
As California’s only authorized Hoot manufacturer and distributor, Superior On-Site Solutions is the direct source for Hoot systems and components for licensed septic contractors across the state. We manufacture tanks here in California, which means shorter lead times, better coordination, and a direct line to the people who actually built the system — not a regional rep several states away.
We understand that your job site doesn’t run on someone else’s schedule. We work to make the supply, documentation, and support side of a Hoot installation as straightforward as possible, so you can focus on the installation itself. Call us at 916-436-8457 to discuss your next project.
Statewide tank delivery available. We deliver Hoot systems and components to job sites throughout California — whether you’re in our full-service area or working in a county we don’t regularly cover for O&M service.
Systems & Components Available
We carry the full Hoot product line and the components needed to complete a proper installation. Available systems and parts include:
Hoot BNR Systems
H600 through H1200 configurations. Single and two-tank setups available depending on site flow requirements and county specifications.
Hoot ANR Systems
H600 through H1200 in Advanced Nitrogen Reduction configurations. Available in 450 GPD, 675 GPD, and 900 GPD for nitrogen-sensitive sites.
Blowers & Diffusers
Replacement and new-installation blowers and diffuser assemblies sized to the specific system configuration.
Control Panels & Sensors
Hoot control panels, liquid sensor probes, floats, alarms, and county-required monitoring components.
Pumps
Effluent pumps for discharge to drip dispersal or other county-approved dispersal methods.
Lids, Risers & Access
Replacement lids, risers, and grade rings for new installations and existing system upgrades.
Installation Support
We don’t hand you a tank and walk away. Our team is available to support you through the installation process — from pre-job questions to county inspection prep. Support includes:
- Wiring diagrams and blower specifications for each system configuration
- Control panel startup assistance — phone or on-site as needed
- Troubleshooting support during and after installation
- County inspection preparation and documentation review
- Photo or layout review for unusual site conditions
- Job-site delivery coordination throughout California
Contractor Training
If you’re new to installing Hoot systems or want to get your crew up to speed, we offer contractor training that covers everything you need to install and hand off a Hoot system with confidence. Training topics include:
System Components
A walkthrough of every component in the Hoot system — what it does, where it goes, and how it connects to the overall treatment process.
Blower & Aeration Setup
Proper blower installation, airflow settings, and diffuser placement for optimal aeration chamber performance.
O&M Requirements
What California counties require for ongoing operation and maintenance — so you can set proper expectations with your clients at handoff.
County Expectations
What inspectors look for, what documentation is required, and how to navigate the permit and inspection process in the counties we serve.
Technical Documents & Resources
The documents below are available for licensed septic contractors working with Hoot systems. For additional documentation or project-specific support, call us at 916-436-8457.
📋 Installation Guides & Checklists
Hoot System Installer’s Guide
Complete installation guide for Hoot advanced treatment systems — the primary reference for every Hoot installation.
Download PDF →SOS Supplemental Installer’s Guide
SOS-specific installation notes and field guidance to supplement the standard Hoot installer’s guide.
Download PDF →SOS Delivery Checklist
Step-by-step checklist for verifying system components and condition at the time of tank delivery to the job site.
Download PDF →SOS Installation Checklist
Comprehensive installation checklist covering every step from tank setting through county inspection sign-off.
Download PDF →FAQ — Designers & Contractors
Answers to the most common questions from contractors and designers working with Hoot systems in California.
Download PDF →🔧 Technical Documents
Hoot Basic Wiring Diagram
Standard wiring diagram for Hoot control panel, blower, pump, and alarm connections for all system configurations.
Download PDF →Hoot Drip Disposal Design & Installation Guide
Complete design and installation guide for Hoot systems using GeoFlow subsurface drip dispersal.
Download PDF →📐 BNR Spec Sheets by System
H600BNR — 1-Tank Complete System
Specifications for the single-tank H600 BNR configuration. The most compact Hoot option for standard residential applications.
Download PDF →H600BNR — 2-Tank Complete System
Specifications for the two-tank H600 BNR configuration for sites requiring additional tank capacity or separation.
Download PDF →H750BNR Spec Sheet
Specifications for the H750 BNR system for higher-flow residential and light commercial applications.
Request Spec Sheet →H900BNR Spec Sheet
Specifications for the H900 BNR system for larger residential and multi-bedroom applications.
Request Spec Sheet →H1000BNR Spec Sheet
Specifications for the H1000 BNR system for high-flow residential, ADU, and commercial applications.
Request Spec Sheet →H1200BNR Spec Sheet
Specifications for the H1200 BNR system for the highest-capacity BNR residential and commercial configurations.
Request Spec Sheet →Ready to Work Together?
Call us to discuss your next Hoot installation, request a system quote, or ask about contractor training. We’re here to make the supply and support side of your Hoot projects as smooth as possible.
